ACT Grey 2 meter LSZH U/FTP CAT6A datacenter slimline patch cable snagless with RJ45 connectors

N.º de artículo DC7002
  • Cable length: 2 m
  • Full copper 32AWG wires, 50µ gold RJ-45 contacts
  • Outer diameter jacket of only 3.8mm to improve air flow in cabinets
  • Snagless boots
  • For connecting two active devices e.g. a switch and a nas
  • Specifications comply to international standards
  • Cables are 100% tested
  • 5 Year warranty
CAT6A U/FTP slimline datacenter ethernet cables are smaller in diameter (3.8mm vs 5.9mm) than regular CAT 6A patch cords. The bending radius is lower in comparison with regular patch cords. This results in a better airflow in the server rack/network cabinet.

Although, ISO/IEC and TIA standards describe the use of patch cords between 22 and 28 AWG, it is possible to use 32 AWG patch cables. This results in a higher attenuation, particularly at higher frequencies.
Sin stock Existencias bajas en Stock
Sin stock Existencias bajas en Stock
Disponible desde 19/04/2024
Este producto no puede ser pedido en este momento.
Descripción
  • Cable length: 2 m
  • Full copper 32AWG wires, 50µ gold RJ-45 contacts
  • Outer diameter jacket of only 3.8mm to improve air flow in cabinets
  • Snagless boots
  • For connecting two active devices e.g. a switch and a nas
  • Specifications comply to international standards
  • Cables are 100% tested
  • 5 Year warranty
CAT6A U/FTP slimline datacenter ethernet cables are smaller in diameter (3.8mm vs 5.9mm) than regular CAT 6A patch cords. The bending radius is lower in comparison with regular patch cords. This results in a better airflow in the server rack/network cabinet.

Although, ISO/IEC and TIA standards describe the use of patch cords between 22 and 28 AWG, it is possible to use 32 AWG patch cables. This results in a higher attenuation, particularly at higher frequencies.
Especificaciones
Marca ACT
Categoria de producto Latiguillos CAT6A U/FTP
Longitud del cable 2 m
Tipo de conector RJ45
Conector A RJ45 male (x1)
Conector B RJ45 male (x1)
Superficie de contacto Gold plated
Connector contact plating Gold plated
Ciclos de inserción 750
Tipo de apantallado U/FTP
Categoría CAT6A
Material del conductor Copper
Calibre de cable 32 AWG
Cubierta exterior LSZH
Impedancia 100 Ω
Ancho de banda 500 MHz
Color del cable Grey
Número de color RAL 7035
Temperatura mínima de trabajo -20 °C
Temperatura máxima de trabajo 75 °C